Safety Information
The products described in this manual can fail in a variety of modes due to misuse, age, or malfunction and is not
designed or intended for used in systems requiring fail-safe performance, including life safety systems. Systems
with the products must be designed to prevent personal injury and property damage during product operation
and in the event of product failure.
Warning! Verify power is OFF before connecting or disconnecting the interface or RF cables.
Warranty Information
FreeWave Technologies, Inc. warrants the FreeWave® ZumLink Z9-PC or Z9-PC-SR001 (Product) that you have
purchased against defects in materials and manufacturing for a period of two years from the date of shipment,
depending on model number. In the event of a Product failure due to materials or workmanship, FreeWave will,
at its discretion, repair or replace the Product. For evaluation of Warranty coverage, return the Product to
FreeWave upon receiving a Return Material Authorization (RMA). The replacement product will remain under
warranty for 90 days or the remainder of the original product warranty period, whichever is longer.
IN NO EVENT WILL FREEWAVE TECHNOLOGIES, INC., ITS SUPPLIERS,OR ITS LICENSORS BE LIABLE FOR ANY DAMAGES ARISING
FROM THE USE OF OR INABILITY TO USE THIS PRODUCT. THIS INCLUDES BUSINESS INTERRUPTION,LOSS OF BUSINESS
INFORMATION,INABILITY TO ACCESS OR SEND COMMUNICATION OR DATA,PERSONAL INJURY OR DAMAGE,OR OTHER LOSS
WHICH MAY ARISE FROM THE USE OF THIS PRODUCT. THE WARRANTY IS EXCLUSIVE AND ALL OTHER WARRANTIES EXPRESS
OR IMPLIED,INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE
ARE EXPRESSLY DISCLAIMED.
FreeWave’s Warranty does not apply in the following circumstances:
1. If Product repair, adjustments, or parts replacements are required due to accident, neglect, or undue
physical, electrical, or electromagnetic stress.
2. If Product is used outside of FreeWave specifications as stated in the Product's data sheet.
3. If Product has been modified, repaired, or altered by Customer unless FreeWave specifically authorized
such alterations in each instance in writing. Where applicable, this includes the addition of conformal
coating.
Warning! The Z9-PC / Z9-PC-SR001 are sold as a multi-board solution, assembled at the FreeWave
factory. Any alteration, including the separation of the individual boards, voids the FreeWave
warranty.
FreeWave Technologies, Inc.
5395 Pearl Parkway, Suite 100
Boulder, CO 80301
303.381.9200
Toll Free: 1.866.923.6168
Fax: 303.786.9948
Copyright © 2018 by FreeWave Technologies, Inc.
All rights reserved. www.freewave.com
Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 3 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Table of Contents
Preface 12
1. Overview 14
1.1. Communication Method 15
1.2. ZumBoost Technology 15
1.2.1. Adaptive Spectrum Learning 15
1.2.2. Forward Error Correction 15
1.2.3. Packet Aggregation 15
1.2.4. Packet Compression 16
1.3. ZumIQ Application Environment 16
2. Included & User-supplied Equipment 17
2.1. Included Equipment 17
2.2. User-supplied Equipment 17
3. Port Connections and Pinout Assignments 18
3.1. Z9-PC and Z9-PC-SR001 Port Connections 19
3.2. Z9-PC and Z9-PC-SR001 COM1 and COM2 Pinout Assignments 20
Z9-PC and Z9-PC-SR001 J4 Power / Ethernet Pinout Assignments 22
4. Installation 24
4.1. Power Setup 25
4.2. Installation 25
5. Firmware Upgrade 27
5.1. Download the Upgrade File 28
5.2. Upgrade Summary - v1.1.01 31
5.2.1. Downgrade 31
5.2.2. Upgrade 31
5.2.3. Upgrade from Firmware v1.0.7.0 32
5.2.4. Upgrade from Firmware v1.0.6.0 32
5.2.5. Upgrade from Firmware v1.0.4.3 (Z9-PC and Z9-PC-SR001) 33
5.2.6. Upgrade from Firmware v1.0.4.2 (Z9-P and Z9-PE) 33
5.3. Firmware Upgrade - Drag and Drop 34
5.4. Firmware Upgrade - Web Interface 40
5.4.1. Setup the Computer IP Address Configuration 41
5.4.2. Install the Upgrade File using the Web Interface 45
6. Configuration 51
6.1. Drag and Drop Configuration - ZumLink 52
6.2. Drag and Drop Configuration - ZumIQ 58
6.3. CLI Configuration 64
6.3.1. Connect the Z9-PC / Z9-PC-SR001 to the Computer 64
Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 4 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
6.3.2. Tera Term Activation and ZumLink Setup 65
6.3.3. Tera Term Activation and ZumIQ Setup 70
6.4. Web Interface Configuration 74
6.4.1. Connect the Z9-PC / Z9-PC-SR001 to the Computer 75
6.4.2. Setup the Computer IP Address Configuration 76
6.4.3. Web Interface Configuration - Z9-PC / Z9-PC-SR001 80
7. Creating a Basic ZumLink Gateway and Endpoint Network 84
8. ZumIQ Application Environment 86
8.1. Optional: Download the ZumIQ Application Environment 87
8.2. Optional: Drag and Drop - Installation of ZumIQ Application Environment 89
8.3. Optional: Web Interface - Installation of ZumIQ Application Environment 92
8.4. Activating ZumIQ 97
8.5. Verify ZumIQ Activation 99
8.6. Using ZumIQ as DEVUSER 101
9. Web Interface Administration 103
9.1. Access the Web Interface 104
9.2. Change the COM Parameters 106
9.3. Change the Data Path Parameters 110
9.4. Change the Encryption Parameters 113
9.5. Change the Local Diagnostics 116
9.6. Change the Network Parameters 119
9.7. Change the NTP Parameters 122
9.8. Change the Radio Settings Parameters - Endpoints 125
9.9. Change the Radio Settings Parameters - Endpoint-Repeaters 129
9.10. Change the Radio Settings Parameters - Gateways 133
9.11. Change the Radio Settings Parameters - Gateway-Repeaters 137
9.12. Change the Security Parameters 141
9.13. Change the Services Parameters 144
9.14. Change the SNMP Parameters 147
9.15. Change the System Info Parameters 150
9.16. Change the Terminal Server Relay Parameters 153
10. Change the Passwords 156
10.1. Change the ADMIN Password 157
10.2. Change the DEVUSER Password 157
11. IP Filtering 158
11.0.1. Example: Network Topology with Traffic at the Gateway 162
12. Repeaters 163
12.1. Repeater - Setup Table 165
12.1.1. Hopping OFF Repeater Setup 165
Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 5 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
12.1.2. Hopping ON Repeater Setup 166
12.2. Basic Gateway and Endpoint-Repeater Setup 168
12.2.1. Open a Terminal Emulator Application 169
12.2.2. Hopping On: Gateway and Endpoint-Repeater Setup 172
12.2.3. Hopping Off: Gateway and Endpoint-Repeater Setup 174
12.3. Repeater - Examples 176
12.3.1. Gateway-Repeater 177
12.3.2. Endpoint-Repeater 178
12.3.3. Multiple Repeaters: Gateway-Repeater and Endpoint-Repeater 179
12.3.4. Multiple Repeaters: Four Endpoint-Repeaters 180
13. Approved Antennas 181
13.0.1. Omni-Directional Antennas 181
13.0.2. Directional Antennas 181
13.0.3. Alternative Antennas 182
14. COM Parameters 183
14.1. baudrate 184
14.2. breakBeforeSendUs 184
14.3. connectionDrops 185
14.4. databits 186
14.5. delayBeforeSendMs 186
14.6. duplex 187
14.7. flowControl 188
14.8. handler 188
14.9. mode 190
14.10. parity 191
14.11. RxBytes 191
14.12. stopbits 192
14.13. TerminalServerPort 192
14.14. TerminalServerTimeOut 193
14.15. TxBytes 194
15. config Parameters 196
15.1. addTraceMask 197
15.2. factoryDefaults 197
15.3. getCurrentConfig 197
15.4. handleDragDrop 197
15.5. licenseState 197
15.6. loadConfig 198
15.7. removeTraceMask 198
15.8. reset 198
Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 6 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
15.9. restore 199
15.10. save 200
16. dataPath Parameters 201
16.1. aggregateEnabled 202
16.2. compressionEnabled 203
16.3. fecRate 204
16.4. MacTableEntryAgeTimeout 206
16.5. otaMaxFragmentSize 207
16.6. routeMinSignalMarginThresh 207
17. date Parameters 209
17.1. dcAppStartTime 210
17.2. dcAppUptime 210
17.3. time 211
17.4. timeString 211
17.5. upTime 212
17.6. upTimeString 212
18. encryption Parameters 214
18.1. activeKey 215
18.2. encryptionMode 215
18.3. getKey 216
18.4. remoteRestore 217
18.5. remoteSave 217
18.6. setKey 217
19. localDiagnostics Parameters 219
19.1. signalLevel 220
19.2. signalMargin 220
19.3. cntBadBCC 221
19.4. cntBadSync 221
19.5. cntETX 221
19.6. cntSTX 221
19.7. getStats 221
19.8. interfaceBytesRx 222
19.9. interfaceBytesTx 222
19.10. interfaceDataRx 222
19.11. interfaceDataTx 222
19.12. MacTableClear 223
19.13. MacTableShow 223
19.14. monitoredNode 224
19.15. noiseLevel 224
Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 7 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
19.16. RadioAckTx 225
19.17. RadioBadAckRx 225
19.18. RadioBadCRC 226
19.19. RadioBadSync 226
19.20. RadioContentionDrop 227
19.21. RadioLLRx 227
19.22. RadioLLTx 228
19.23. RadioNoAckTx 229
19.24. RadioReliableRx 229
19.25. RadioReliableTx 229
19.26. RadioRexmit 229
19.27. RadioRx 229
19.28. RadioSendingDrop 230
19.29. RadioTimedOut 230
19.30. RadioTooLong 230
19.31. RadioTooShort 230
19.32. RadioTx 230
19.33. resetsDetected 231
19.34. resetSent 231
19.35. resetStats 231
19.36. RxSuccess 232
19.37. showChannelDiags 232
19.38. showNodeDiags 233
19.39. timestamp 233
19.40. TxAvailability 234
19.41. TxSuccess 235
19.42. VSWR 235
20. network Parameters 237
20.1. gateway 238
20.2. ip_address 238
20.3. mac_address 239
20.4. MTU 239
20.5. nameserver_address1 240
20.6. nameserver_address2 241
20.7. netmask 241
20.8. netmaskFilterEnabled 242
20.9. stpEnabled 243
20.10. txqueuelen 244
21. networkStats Parameters 245
Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 8 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
21.1. rx_bytes 246
21.2. rx_dropped 246
21.3. rx_errors 247
21.4. rx_packets 247
21.5. tx_bytes 248
21.6. tx_dropped 248
21.7. tx_errors 249
21.8. tx_packets 249
22. NTP Parameters 250
22.1. ntp_address 251
22.2. ntpDate 252
22.3. ntpReference 252
22.4. ntpRestart 253
23. radioSettings Parameters 254
23.1. beaconBurstCount 255
23.2. beaconInterval 256
23.3. frequencyKey 257
23.4. frequencyMasks 259
23.5. lnaBypass 261
23.6. maxLinkDistanceinMiles 262
23.7. networkId 263
23.8. nodeId 264
23.9. radioFrequency 265
23.10. radioHoppingMode 267
23.11. radioMaxRepeaters 269
23.12. radioMode 272
23.13. radioRepeaterSlot 273
23.14. rfDataRate 274
23.15. txPower 277
24. radioSettingsHelpers Parameters 279
24.1. frequencyMasksErrors 280
24.2. rCli 280
24.3. resetRadio 280
24.4. setAllRadioSettings 280
24.5. syncSettingsFromRadio 280
25. runtimeEnvironment Parameters 281
25.1. rteInstalledByAppsVersion 282
25.2. rteReset 282
25.3. rteTemplateVersion 283
Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 9 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
25.4. rteVersion 284
26. security Parameters 285
26.1. enableEthernetLogin 286
26.2. enablePtpInterface 286
27. services Parameters 288
27.1. timeOutCli 289
28. SNMP Parameters 290
28.1. roCommunityName 291
28.2. rwCommunityName 291
28.3. snmpUser 292
28.4. v1Enabled 293
28.5. v2cEnabled 294
28.6. v3Enabled 294
29. system Parameters 296
29.1. dump 297
29.2. dumpFormat 297
29.3. dumpPage 298
29.4. dumpTag 299
29.5. dumpTopic 299
29.6. filter 299
29.7. help 300
29.8. login 300
29.9. logout 300
29.10. modbusLayout 301
29.11. pages 301
29.12. password 301
29.13. passwordRestoreDefaults 302
29.14. showLayout 303
29.15. tags 303
29.16. whoami 303
30. systemInfo Parameters 304
30.1. deviceConfiguration 305
30.2. deviceFirmwareVersion 305
30.3. deviceId 306
30.4. deviceModel 306
30.5. deviceName 307
30.6. hopTableVersion 307
30.7. layoutHash 308
30.8. licenses 308
Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 10 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
30.9. modelCode 309
30.10. radioFirmwareVersion 310
30.11. radioModel 310
30.12. radioModelCode 311
30.13. radioSerialNumber 311
30.14. resetInfo 312
30.15. rteTemplateVersion 312
30.16. rteVersion 312
30.17. serialNumber 313
31. TerminalServerRelay Parameters 314
31.1. remote_termserv_ip_address 315
31.2. termserv_relay_mapping 315
32. Examples - Terminal Server Relay 318
32.1. Connected Terminal Servers and Terminal Server Relay 319
32.2. LOCAL_BOTH_COM_TO_REMOTE_BOTH_COM 320
32.3. LOCAL_COM1_TO_REMOTE_COM1 321
32.4. LOCAL_COM2_TO_REMOTE_COM2 322
32.5. LOCAL_BOTH_COM_TO_REMOTE_COM1 323
32.6. LOCAL_BOTH_COM_TO_REMOTE_COM2 324
32.7. LOCAL_COM1_TO_REMOTE_BOTH_COM 325
32.8. LOCAL_COM2_TO_REMOTE_BOTH_COM 326
32.9. Example: Multicast 327
33. Web Interface 328
33.1. COM window 329
33.2. Config window 331
33.3. Data Path window 333
33.4. Date window 335
33.5. Encryption window 337
33.6. File Upload window 339
33.7. Help window 341
33.8. Home window 343
33.9. Local Diagnostics window 344
33.9.1. Upper Half 345
33.9.2. Lower Half 346
33.10. Network window 347
33.11. Network Diagnostics window 349
33.12. Network Stats window 351
33.13. NTP window 353
33.14. Radio Settings window 355
Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 11 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
33.14.1. Gateway Radio Mode 356
33.14.2. Endpoint Radio Mode 357
33.15. Radio Settings Helpers window 358
33.16. Runtime Environment window 360
33.17. Security window 361
33.18. Services window 363
33.19. SNMP window 365
33.20. System Info window 367
33.21. Terminal Server Relay window 369
33.22. User Data - Drag and Drop window 371
34. Release Notes 373
34.1. Version 1.1.01 373
34.2. Version 1.0.7.0 377
34.3. Version 1.0.4.3 (Initial Release) 380
35. Mechanical Drawing - Z9-PC 381
35.1. Z9-PC 381
35.2. Z9-PC-SR001 382
36. Hop Tables 383
36.1. Standard Hop Set - ZumLink 900MHz Channels 384
36.1.1. RF Data Rate: 115.2 kbps 384
36.1.2. RF Data Rate: 250 kbps 385
36.1.3. RF Data Rate: 500 kbps 385
36.1.4. RF Data Rate: 1 Mbps 386
36.1.5. RF Data Rate: 1.5 Mbps 386
36.1.6. RF Data Rate: 4 Mbps 387
37. ZumLink MIB 388
37.1. CPU Usage 389
37.2. Disk Usage 390
37.3. Memory Usage 392
37.4. FreeWave Technologies-MIB 394
37.5. SNMP Write Access 410
Appendix A: Technical Specifications 412
Appendix B: LEDs 416
Normal Operation 416
Z9-PC-SR001 RJ-45 Ethernet Connector LEDs 417
Appendix C: Z9-PC / Z9-PC-SR001 Files and Descriptions 418
Appendix D: FreeWave Legal Information 420
www.freewave.com more fo@freewave.com Note: Use the httg://sug@rt.freewave.coml website to download the latest documentation for 29- PC / ZQ—PC-SROOL Registration is required to use this website.
Z9-PC / Z9-PC-SR001
User & Reference Manual
Preface
Contact FreeWave Technical Support
For up-to-date troubleshooting information, check the Support page at www.freewave.com.
FreeWave provides technical support Monday through Friday, 8:00 AM to 5:00 PM Mountain
Time (GMT -7).
lCall toll-free at 1.866.923.6168.
lIn Colorado, call 303.381.9200.
lContact us through e-mail at moreinfo@freewave.com.
Additional Information
Note: Use the http://support.freewave.com/ website to download the latest documentation for Z9-
PC / Z9-PC-SR001.
Registration is required to use this website.
Document Styles
This document uses these styles:
lParameter setting text appears as: [Page=radioSettings]
lFile names appear as: configuration.cfg.
lFile paths appear as: C:\Program Files (x86)\FreeWave Technologies.
lUser-entered text appears as: xxxxxxxxx.
LUM0077AA Rev Sep-2018 Page 12 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Caution: Indicates a situation that MAY cause damage to personnel, the radio, data, or network. Example: Provides example information of the related text. FREEWAVE Recommends: Identifies FreeWave recommendation information. ‘ lmportantl: Provides cmcial information relevant to the text or procedure. ‘ Note: Emphasis of specific information relevant to the text or procedure. \. - I, v Provides time saving or informative suggestions about using the product. ®
Preface Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 13 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Caution: Indicates a situation that MAY cause damage to personnel, the radio, data, or
network.
Example: Provides example information of the related text.
FREEWAVE Recommends: Identifies FreeWave recommendation information.
Important!: Provides crucial information relevant to the text or procedure.
Note: Emphasis of specific information relevant to the text or procedure.
Provides time saving or informative suggestions about using the product.
Warning! Indicates a situation that WILL cause damage to personnel, the radio, data, or
network.
Z9-PC / Z9-PC-SR001
User & Reference Manual
1. Overview
Thank you for purchasing the FreeWave Z9-PC / Z9-PC-SR001.
ZumLink is the latest generation of radios offered by FreeWave and consists of enclosed and
board level radios.
lZ9-PC is a board level 900MHz OEM Ethernet radio module.
lZ9-PC-SR001 is a board level 900MHz OEM Ethernet radio module with an RJ-45
Ethernet connector.
The Z9-PC or Z9-PC-SR001 are radio modules ideally suited for OEM applications where it will
be embedded in the OEM product. It is built with the smallest possible footprint and with minimal
industry standard physical connectivity. The intent is for the user to design their own custom
interface to the radio module.
The interface board in the Z9-PC-DEVKIT is not intended to be used in the field. Rather it is a
temporary mechanism to allow a user to evaluate the radio modules without needing to first
design their own interface. If the user desires a ZumLink Ethernet product that has industry
standard connectivity built-in, models Z9-P or Z9-PE should be considered.
The Z9-PC / Z9-PC-SR001 900MHz Series:
lOperates in the unlicensed 900MHz ISM band (902-928 MHz).
lProvides a maximum of 30dBm transmit output power.
lIs FCC compliant as both a Frequency Hopping Spread Spectrum (FHSS) and a Digital
Modulating (DM) radio.
lProvides ZumIQ, a Linux-based application environment for the deployment of applications
at the edge
lHas one Ethernet port, two serial ports, and one micro USB port.
LUM0077AA Rev Sep-2018 Page 14 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Note: The frequency hopping capability is available at all bandwidths and the single channel (DM) operation is available for bandwidths of at least 500 kHz.
1. Overview Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 15 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Note: The frequency hopping capability is available at all bandwidths and the single channel (DM)
operation is available for bandwidths of at least 500 kHz.
1.1. Communication Method
ZumLink uses Listen Before Talk (LBT) and Carrier Sense Multiple Access (CSMA) where there
are no assigned slots. The radios transmit when the channel is clear.
lThe Gateway broadcasts packets to all Endpoints within range.
lThe Endpoints unicast packets back to the Gateway.
lThe Gateway acknowledges the Endpoint packets.
FreeWave’s traditional protocol has a Gateway Time Slot and an Endpoint Time Slot within a
frame.
lThe Gateway transmits in its slot and listens in the Endpoint slot.
lThe Endpoint transmits its slot and listens in the Gateway slot.
1.2. ZumBoost Technology
ZumLink incorporates ZumBoost technology using four performance-enhancing algorithms used
together or independently to improve throughput in the most demanding RF environments:
1.2.1. Adaptive Spectrum Learning
lLearns which RF signals are part of the ZumLink network and which are not, reducing bad
packets and retransmissions.
lStandard on all ZumLink radios, the "Listen Before Talk" algorithm provides spectrum
monitoring, delivering network intelligence and increasing throughputs in noisy
environments.
1.2.2. Forward Error Correction
lThe fecRate (on page 204) increases the reliability of the data transferred over the air at the
cost of some transmission throughput.
lImproves sensitivity by 3dB to maximize range and link range in noisy environments.
lAdds redundant information to a data stream to detect packet errors and corrects them to
avoid retransmission of the packet.
1.2.3. Packet Aggregation
lThe aggregateEnabled (on page 202) setting increases throughput of small packets by
combining multiple packets into a single packet minimizing the number of packets required
for transmission.
lDoes NOT affect medium and large packets.
Note: Any applicalxon usxng a Linux—compalxble language can be housed in ZumIQ.
1. Overview Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 16 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
1.2.4. Packet Compression
lWhen the compressionEnabled (on page 203) setting is enabled, the outgoing packets are
analyzed and, if the data packet can be compressed, sent compressed to transmit fewer
bits over the air.
1.3. ZumIQ Application Environment
ZumLink provides the ZumIQ Application Environment that allows for the development and
deployment of Linux-based applications onto the radio. The application has access to the same
computing resources as the radio but is in a segregated section of the Z9-PC / Z9-PC-SR001.
Note: Any application using a Linux-compatible language can be housed in ZumIQ.
Included Equipment Qty Description ’l Z9-PC / Z9—PC-SR001 wireless device. 1 Power Cable with flying leads Quick Start Guide Note: "See Approved Antennas (on page 181 ) for detailed information. Approved antennas can be purchased directly from FreeWave.
Z9-PC / Z9-PC-SR001
User & Reference Manual
2. Included & User-supplied Equipment
2.1. Included Equipment
Included Equipment
Qty Description
1 Z9-PC / Z9-PC-SR001 wireless device.
1 Power Cable with flying leads
1 Quick Start Guide
2.2. User-supplied Equipment
lInterface / Power Cables
lUSB to micro-USB cable
lFCC approved antenna **
lComputer
Note: **See Approved Antennas (on page 181) for detailed information.
Approved antennas can be purchased directly from FreeWave.
LUM0077AA Rev Sep-2018 Page 17 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Z9-PC / Z9-PC-SR001
User & Reference Manual
3. Port Connections and Pinout Assignments
Port Connections
lZ9-PC and Z9-PC-SR001 Port Connections (on page 19)
Pinout Assignments
lZ9-PC and Z9-PC-SR001 COM1 and COM2 Pinout Assignments (on page 20)
lZ9-PC and Z9-PC-SR001 J4 Power / Ethernet Pinout Assignments (on page 22)
LUM0077AA Rev Sep-2018 Page 18 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
‘ lmponantl: The RJ -45 connector is NOT installed on the ZQ—PC. Mlcm-USB Connector RJ45 Ethernet Connector (ZQ-FC-SRUM only) {Not an Ihs ZS DEV MMCX RF Connector D4-Elhemet link LEDs Da-Power D2~Caniel omen (CD) Serial Pan Sena‘ Pan COM 1 COM 2 Ememel/ Power
3. Port Connections and Pinout Assignments Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 19 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
3.1. Z9-PC and Z9-PC-SR001 Port Connections
Important!: The RJ-45 connector is NOT installed on the Z9-PC.
Warning! The Micro-USB Connector shield is connected to a Common Ground NOT a
Chassis Ground.
Figure 1: Z9-PC / Z9-PC-SR001 Port Connections
©©®©® @@@@@ @@@@@ @@@@® JZ-Serial COM 1 J3-5erial COM 2 Note: The information in me table refers io ihe Serial Ports in Figure 2. Z9-FC I Z9-FC-SR001 Serial Port Pinout Assignments Pin Number R5232 Description 1 NC Do Noi Conneci 2 CD (0) Carrier detect ouipui
3. Port Connections and Pinout Assignments Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 20 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
3.2. Z9-PC and Z9-PC-SR001 COM1 and COM2 Pinout
Assignments
Figure 2: Z9-PC / Z9-PC-SR001Pinout Assignments
Note: The information in the table refers to the Serial Ports in Figure 2.
l(I) - Input
l(O) - Output
Z9-PC / Z9-PC-SR001 Serial Port Pinout Assignments
Pin Number RS232 Description
1 NC Do Not Connect
2 CD --- (O) Carrier detect output
Z9-FC IZ9-FC-SR001 Serial Port Pinout Assignmen's Pin Number R5232 Descripfion 3 RTS —- (I) RequesI to send inpuI 4 TXD —- (O) TransmiI data output 5 CTS —- (O) Clearto send oquuI 6 RXD —- (I) Receive daIa inpuI 7 GND Ground 8 DTR (I) DaIa Ierminal ready inpuI 9 NC Do NoI ConnecI 10 GND Ground
3. Port Connections and Pinout Assignments Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 21 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Z9-PC / Z9-PC-SR001 Serial Port Pinout Assignments
Pin Number RS232 Description
3 RTS --- (I) Request to send input
4 TXD --- (O) Transmit data output
5 CTS --- (O) Clear to send output
6 RXD --- (I) Receive data input
7 GND Ground
8 DTR --- (I) Data terminal ready input
9 NC Do Not Connect
10 GND Ground
Pin 1 Pin 2 ©®®QO ©36®® @®@g@ @@@®@ J2Senal COM 1 JESenal COM 2 J4-PuweMEIhernei Note: The information in me table refers io ihe Serial Ports in Figure 3.
3. Port Connections and Pinout Assignments Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 22 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Z9-PC and Z9-PC-SR001 J4 Power / Ethernet Pinout Assignments
Figure 3: Z9-PC / Z9-PC-SR001J4-Power / EthernetPinout Assignments
Note: The information in the table refers to the Serial Ports in Figure 3.
Z9-FC I Z9-FC-SR001 J4—Powerl Ethernet Finout Assignments Pin Number Assignment Signal Description 1 3+ (Power Input) Input +5 to +12 VDC (210%) 2 GND GND Ground 3 NC Do Not Connect Reserved for future use. 4 NC Do Not Connect Reserved for future use. 5 GND GND Ground 6 RX— Input Receive minus line for Ethernet 7 RX+ Input Receive plus line for Ethernet 8 GND GND Ground 9 TX— Output Transmit minus line for Ethernet 10 TX+ Output Transmit plus line for Ethernet
3. Port Connections and Pinout Assignments Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 23 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Z9-PC / Z9-PC-SR001J4-Power / EthernetPinout Assignments
Pin Number Assignment Signal Description
1 B+ (Power Input) Input +5 to +12 VDC (±10%)
2 GND GND Ground
3 NC Do Not Connect Reserved for future use.
4 NC Do Not Connect Reserved for future use.
5 GND GND Ground
6 RX- Input Receive minus line for Ethernet
7 RX+ Input Receive plus line for Ethernet
8 GND GND Ground
9 TX- Output Transmit minus line for Ethernet
10 TX+ Output Transmit plus line for Ethernet
Z9-PC / Z9-PC-SR001
User & Reference Manual
4. Installation
lPower Setup (on page 25)
lInstallation (on page 25)
LUM0077AA Rev Sep-2018 Page 24 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
FREEWAVE Recommends: All input power supply wires should be at least ZOAWG wires. A dedicated and stable power supply line is preferred. The power supply used MUST provide more current than the amount of current drain listed in the specifications for the product and voltage. (at least 350 mA at 12V) @ t', ‘ Note: Power is shared on the Ethernet / Power 10-pin header. Note: The ZQ—PC / ZQ—PC-SR001 is approved to operate with an input voltage range of +5 to +12 VDC (110%) that can supply at least 0.8 Amps. FREEWAVE Recommends: All input power supply wires should be at least ZOAWG wires. A dedicated and stable power supply line is preferred. The power supply used MUST provide more current than the amount of current drain listed in the specifications forthe product and voltage. Note: See LEDs (on page 416) for more information.
4. Installation Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 25 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
4.1. Power Setup
lThe Z9-PC / Z9-PC-SR001 is approved to operate with an input voltage range of +5 to +12
VDC (±10%) that can supply at least 0.8 Amps.
lSee the Technical Specifications (on page 412) for additional information.
FREEWAVE Recommends: All input power supply wires should be at least 20AWG wires.
A dedicated and stable power supply line is preferred.
The power supply used MUST provide more current than the amount of current drain listed in the
specifications for the product and voltage. (at least 350 mA at 12V)
Warning! Use electrostatic discharge (ESD) protectors to protect the radio from electric shock
and provide filtered conditioned power with over-voltage protection.
4.2. Installation
1. Install an FCC-approved antenna.
2. Connect the antenna feed line to the ZumLink.
Warning! Only FCC approved antennas may be used. See Approved Antennas (on
page 181).
The antenna must be professionally installed on a fixed, mounted, and permanent
outdoor structure to satisfy RF exposure requirements.
Any antenna placed outdoors must be properly grounded.
Use extreme caution when installing antennas and follow all instructions included with
the antenna.
If installing a directional antenna, preset the antenna’s direction appropriately.
3. Connect the Z9-PC / Z9-PC-SR001 to a power supply.
Note: Power is shared on the Ethernet / Power 10-pin header.
Note: The Z9-PC / Z9-PC-SR001 is approved to operate with an input voltage range of +5 to
+12 VDC (±10%) that can supply at least 0.8 Amps.
FREEWAVE Recommends: All input power supply wires should be at least 20AWG wires.
A dedicated and stable power supply line is preferred.
The power supply used MUST provide more current than the amount of current drain listed in
the specifications for the product and voltage.
The LED lights blink to show startup.
Note: See LEDs (on page 416) for more information.
lmponantl: The USB does NOT power the ZQ-PC /ZQ-PC-SR001. It only pmvides a configuration interface. figmmmmp, mm; 7 D X m. mm: o * X 1 “‘qu'lm Ml II 33:13:!" ""133“ m, g -' w My” n, "W“ 2 m, numwmm g 9 x : T a» Fva-uflmrnlfi. v; , l , l l » .UIKDVM h T” V' mm: M...” tn m A u l. 7 l l nuvurwro m xx , firr—wmnmmlm 31mm” m l AB Hammond. m l"; w 9mm“ ‘MVKHg-(mml an m A u n 5m [1 ; lmponantl: The driver installs automatically. .. 1mm wzsmm 7 u >< m,="" m.="" o="" x="" i="" elk”="" ml="" 17="" 3323311",="" 4‘="" wwm="" ,="" mw="" .,,="" l="" ‘7="" j="" p="" .="" l-="" wnw.="" a="" ww,="" _="" mm="" ~="" ,="" mm="" m:="" -_="" axle)="" a="" mew».="" emu:="" m1="">
4. Installation Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 26 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
4. Connect the USB cable to the computer and the Micro USB end to the Z9-PC / Z9-PC-
SR001.
The FreeWave Drivers and ZumLink windows may open.
Important!: The USB does NOT power the Z9-PC / Z9-PC-SR001. It only provides a
configuration interface.
The FreeWave Drivers and ZumLink windows may open.
Figure 4: AutoPlay FreeWave Drivers window
Important!: The driver installs automatically.
Figure 5: ZumLink window
5. Optional: Use the Ethernet port for data communications.
6. Continue with:
lFirmware Upgrade (on page 27)
lDrag and Drop Configuration - ZumLink (on page 52)
lCLI Configuration (on page 64)
lWeb Interface Configuration (on page 74)
Importantl: The Download procedure must be completed first.
Z9-PC / Z9-PC-SR001
User & Reference Manual
5. Firmware Upgrade
Important!: The Download procedure must be completed first.
These are the basic steps to upgrade the Z9-PC / Z9-PC-SR001 firmware:
A. Download the Upgrade File (on page 28)
B. Optional: Download the ZumIQ Application Environment (on page 87)
C. Review the Upgrade Summary - v1.1.01 (on page 31) to know which files are used to
upgrade from a previous firmware version.
D. Complete either the:
Firmware Upgrade - Drag and Drop (on page 34) or
Firmware Upgrade - Web Interface (on page 40)
LUM0077AA Rev Sep-2018 Page 27 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Note: The images in this procedure are for Windows® 10 and/or Firefox®. The dialog boxes and windows appear differently on each computer. httgj/suggorttreewave.oom/ lmportantk Registration is required to use this website. was AVE Haw can we help? Nelplnllis we: AVE How can we help? me has mmn Mme“. Emma pimp: “my.“ mummy.“ Wm
5. Firmware Upgrade Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 28 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
5.1. Download the Upgrade File
Note: The images in this procedure are for Windows® 10 and/or Firefox®.
The dialog boxes and windows appear differently on each computer.
1. Click http://support.freewave.com/.
The Login window opens.
Important!: Registration is required to use this website.
2. Enter the User Name and Password.
Figure 6: FreeWave Login window
3. Click .
A successful Login message briefly appears.
The Help Topics window opens.
4. Click the Firmware link. (Figure 7)
Figure 7: Help Topics window
The Firmware window opens.
5. Click the ZumLink Firmware link. (Figure 8)
FREE AVE mm... Man m... ‘ ZumUnll Flmlware FREE AVE ZumLink Firmware a." n... mm...“ .5: up 199: Firmwaevt 1.0.: "W ' ' “ rpm-sum Finn-amt I Z9-PC Z9-PC-SROO1 Firmware V1.1.0.1 FREE AVE Z9-PC Z9-PC—SR001 Firmware v1.1.0.1 Anxl-ann—ms nummmm
5. Firmware Upgrade Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 29 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Figure 8: Firmware window
The available firmware/software appears in the window. (Figure 9)
Figure 9: Z9-PC / Z9-PC-SR001 Firmware window
6. Click the firmware/software link.
The Firmware Upgrade window opens.
7. Select and click the Firmware_v1_1_0_1 attachment. (Figure 10)
Figure 10: Z9-PC / Z9-PC-SR001 Firmware Upgrade window with
selected Firmware v1_1_0_1 Attachment
Openlng nvmwawuy up >< von="" um="" mm="" to="" open:="" fl]="" rum-.ulqup="" which="" s="" (nmpm="" (zipped)="" folds="" m5="" ml?)="" «mm="" hilp/lsuppmflmrmvzxnm="" wrm="" should="" rum:="" do="" mmmme="" ngenwnh="" mndows="" fxplnmmdwn)="" v="" @sw...="" ;="" ’="" 7="" :="" [3="" do="" lhs="" fimnmmally="" lol="" me="" llkttus="" ham="" nww="" o...="" .mmmmkuwm="" x="" (="" ¢="" u="" w:="" as="">< ,="" ,memfu:="" anwmsnwvwamrm="" v="" .="" mm="" h="" h="" 1,.="" ,7="" mw="" -="" mum="" -="" v="" fizmunmn="" a="" .="" mn="" u="" mm“.="" 111‘="" mm,="" ‘="" mm="" yummyrnj...="" v="" 5mm.="" “wwwyflm-n,="" v="" note:="" the="" .zlp="" file="" includes="" 1he="" .pkg="" and="" .fcffiles="" used="" in="" me="" upgrade="" process.="">
5. Firmware Upgrade Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 30 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
The Opening dialog box opens. (Figure 11)
Figure 11: Opening Firmware v1_1_0_1.zip dialog box
8. Click OK.
The Enter name of file to save to dialog box opens. (Figure 12)
Figure 12: Enter name of file to save to dialog box
9. Search for and select a location to save the .zip file to and click Save.
The Enter name of file to save to dialog box closes.
10. Either:
a. Continue with Optional: Download the ZumIQ Application Environment (on page 87) or
b. Open a Windows® Explorer window and find the location where the Firmware v1_1_
0_1.zip file was saved.
11. Double-click the .zip file.
12. Extract the files from the .zip file into the parent location.
Note: The .zip file includes the .pkg and .fcf files used in the upgrade process.
13. Continue with Upgrade Summary - v1.1.01 (on page 31).
5. Firmware Upgrade Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 31 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
5.2. Upgrade Summary - v1.1.01
5.2.1. Downgrade
Contact FreeWave Technical Support (on page 12) for firmware DOWNGRADE assistance.
5.2.2. Upgrade
Warning! The upgrade file names are numbered 1_, 2_, and 3_ and MUST BE INSTALLED
IN A SPECIFIC NUMERIC ORDER for a successful upgrade.
The UPGRADE options are:
lUpgrade from Firmware v1.0.7.0 (on page 32)
lUpgrade from Firmware v1.0.6.0 (on page 32)
lUpgrade from Firmware v1.0.4.3 (Z9-PC and Z9-PC-SR001) (on page 33)
lUpgrade from Firmware v1.0.4.2 (Z9-P and Z9-PE) (on page 33)
After deciding the files needed for the Z9-PC / Z9-PC-SR001 upgrade from its installed firmware
version, continue with either:
lFirmware Upgrade - Drag and Drop (on page 34)
lFirmware Upgrade - Web Interface (on page 40)
lmponanti: Contact FreeWave Technical Support (on page 12) for the ZumIQ license. Note: ZumIQ can be added anytime in future. FREEWAVE Recommends: If currently using the v1.0.6.0 developer environment, an upgrade to 3_Optional_ZumIQ_Environment_v1_1_0_0.pkg is NOT required.
5. Firmware Upgrade Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 32 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
5.2.3. Upgrade from Firmware v1.0.7.0
Required Files
1_Device_Firmware_v1_1_0_1.pkg
2_Radio_Firmware_v1_0_7_1.fcf
Optional: ZumIQ Files
3_Optional_ZumIQ_Environment_v1_1_0_0.pkg
Important!:Contact FreeWave Technical Support (on page 12) for the ZumIQ license.
5.2.4. Upgrade from Firmware v1.0.6.0
Required Files
1_Device_Firmware_v1_1_0_1.pkg
2_Radio_Firmware_v1_0_7_1.fcf
Optional: ZumIQ Files
3_Optional_ZumIQ_Environment_v1_1_0_0.pkg
lThe ZumIQ license is preserved
Note: ZumIQ can be added anytime in future.
FREEWAVE Recommends: If currently using the v1.0.6.0 developer environment, an upgrade to
3_Optional_ZumIQ_Environment_v1_1_0_0.pkg is NOT required.
Note: ZumIQ can be added anyttme in future. Contact FreeWave Technical Support (on page 12) for the ZumIQ Itcense. Note: ZumIQ can be added anyttme in future. Contact FreeWave Technical Support (on page 12) for the ZumIQ Itcense.
5. Firmware Upgrade Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 33 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
5.2.5. Upgrade from Firmware v1.0.4.3 (Z9-PC and Z9-PC-SR001)
Required Files
1_Device_Firmware_v1_1_0_1.pkg
2_Radio_Firmware_v1_0_7_1.fcf
Optional: ZumIQ Files
3_Optional_ZumIQ_Environment_v1_1_0_0.pkg
Note: ZumIQ can be added anytime in future.
Contact FreeWave Technical Support (on page 12) for the ZumIQ license.
5.2.6. Upgrade from Firmware v1.0.4.2 (Z9-P and Z9-PE)
Required Files
1_Device_Firmware_v1_1_0_1.pkg
2_Radio_Firmware_v1_0_7_1.fcf
Optional: ZumIQ Files
3_Optional_ZumIQ_Environment_v1_1_0_0.pkg
Note: ZumIQ can be added anytime in future.
Contact FreeWave Technical Support (on page 12) for the ZumIQ license.
After deciding the files needed for the Z9-PC / Z9-PC-SR001 upgrade from its installed firmware
version, continue with either:
lFirmware Upgrade - Drag and Drop (on page 34)
lFirmware Upgrade - Web Interface (on page 40)
@ FREEWAVE Recommends: Upgrade to v1.1.0.1 to use the enhanced features and updated security of the ZB-PC /ZB-PC-SR001. Prior to an upgrade or downgrade procedure, save and backup all applications. Caution: This procedure requires the Windows® Explorer file extension to be visible. See the Microsoft® topic Show or Hide File Name Extensions to view the extensions. a MW pm ,9, WW a (mum ! rm; K W , firv-ewmnmmm» r LB amt“ m m 9 "M" l My“ m4 vi 5 lm
5. Firmware Upgrade Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 34 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
5.3. Firmware Upgrade - Drag and Drop
This is the drag-and-drop procedure to upgrade the Z9-PC / Z9-PC-SR001 firmware.
Warning! The upgrade file names are numbered 1_, 2_, and 3_ and MUST BE INSTALLED
IN A SPECIFIC NUMERIC ORDER for a successful upgrade.
lAlternatively, use the Firmware Upgrade - Web Interface (on page 40) to upgrade the Z9-
PC / Z9-PC-SR001.
lThe images in this procedure are for Windows® 10 and/or Firefox®.
The dialog boxes and windows appear differently on each computer.
FREEWAVE Recommends: Upgrade to v1.1.0.1 to use the enhanced features and updated
security of the Z9-PC / Z9-PC-SR001.
Prior to an upgrade or downgrade procedure, save and backup all applications.
Caution: This procedure requires the Windows® Explorer file extension to be visible.
See the Microsoft® topic Show or Hide File Name Extensions to view the extensions.
1. Verify the Download the Upgrade File (on page 28) procedure is complete.
2. Connect the USB cable to the computer and the Micro USB end to the Z9-PC Micro-USB
connection.
The FreeWave Drivers and ZumLink windows open.
Figure 13: FreeWave Drivers window
“me , u x .0 X A “1:12” M 33:13:!“ .u V t V nummm rV-y x 3 V » mwummw w ; V .. WW » mm mm, ‘ 1W VV VV ammmml -msw , u x V M. 5m 7 33W.” .0 U X A l W M r .u V V nummm V? X : h V»- muwwxw w ; II Zumhnl mama! " 'r, e A lw‘ in im _m673794v ‘V‘bflrlaulhI/l Yak], u ru =_ osicu g mm ammmm, Wm V M lrl mum/1 Yak], u ru Davy-lam Ym mm Tl Note: This is to backup the current configut before the upgrade process in case the old configut file needs to be restored. Caution: A .pkg or .fcffile extension is required for Windows® 7. A .pkg.txt or .fcf.txt file extension may be required for some versions of Windows® 8, Windows® 8.1, and Windows® 10. Failure to save the file with the correct extension type results in the copied file NOT integrating with the ZQ—PC / ZQ—PC-SR001.
5. Firmware Upgrade Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 35 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Figure 14: ZumLink window
3. In the ZumLink window, double-click the connected Z9-PC / Z9-PC-SR001.
The files of the Z9-PC / Z9-PC-SR001 appear in the window. (Figure 15)
Figure 15: Opened ZumLink window showing the Default Files
4. Optional: Select, copy, and paste the config.txt file to a secure location.
Note: This is to backup the current config.txt before the upgrade process in case the old
config.txt file needs to be restored.
5. Locate and select the downloaded 1_Device_Firmware_v1_1_0_1.pkg upgrade file.
(Figure 16)
Caution: A .pkg or .fcf file extension is required for Windows® 7.
A.pkg.txt or .fcf.txt file extension may be required for some versions of Windows® 8,
Windows® 8.1, and Windows® 10.
Failure to save the file with the correct extension type results in the copied file NOT
integrating with the Z9-PC / Z9-PC-SR001.
6. If using some versions of Windows® 8, Windows® 8.1, or Windows® 10, change the
extension of the .pkg file to .pkg.txt and select that file.
IMMMWWWS 7 n X D gm II I” X ‘ I I Lcwmw flow. 333m.” , 2 mp, W u W WM”, ”W ..;" cm W s" 9mm“ :11 '9 {’1 X E} ' II I b 1 I » my: » am >1ummkruu , mmmmowmum y - mm ‘ ~ w p I1um|inkfls ~ Mm. ” r‘nsmmmsr n,» w. I‘mmm'wfis w‘rm.;.mwlnrwugm gamma». M» m. Wm Juadwfimuwmmm w: m1" :u 37m, "my 'a '1 SVOmuLZum‘lElenanv‘Jrflrflalgmd ”Nu: My man: ILammauumwunnmmmmJuan w: 51: AM Masha mm...“ m, MMMAM mm u: (1 JWMMMMMM m; w? w W ::a jmnwwrwpwvmm MAW» m mu new: «(1 mm, tmmmmmma v u A x : I122: « ‘ 33:21:. , ‘ , BMW .M q.. ..,.....m 2 M : 412:”: M: x- ”:22; « 33:22:; ‘ "' : : 1.": "I "5"'“"‘ L21: nunmmm H ::2. 1.: "V“ ‘ I mmwm 1mm“,m..(.‘mum—ne V: : n ‘ .WM » , :, .omwnwmom ,, , nm_:.m.m.mm. : , : : :: : mmKum : , :
5. Firmware Upgrade Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 36 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Figure 16: Selected 1_Device_Firmware_v1_1_0_1.pkg.txt File
7. Drag and drop the .pkg or .pkg.txt file on to the ZumLink window. (Figure 17)
Figure 17: Drag and Drop the .pkg or .pkg.txt file to the ZumLink window
_ 4025mm ‘1'7 x I- mm .1267)wa » _ mumv =_ am 3 mew»: am an nu: <- ~’r_»rmv(»="" ummmus’z’w="" ,="" l="" l="" lwhnmm="" ,="" ,="" ,="" u="" mvuuhm="" u="" :uqu="" l="" w»:-="" l="" lbymm="" u="" mm="" d="" mmm="" mm="" h="" ;="" caution:="" a="" .pkg="" or="" .fcffile="" extension="" is="" required="" for="" windows®="" 7.="" a="" .pkg.txt="" or="" .fcf.txt="" file="" extension="" may="" be="" required="" for="" some="" versions="" of="" windows®="" 8,="" windows®="" 8.1,="" and="" windows®="" 10.="" failure="" to="" save="" the="" file="" with="" the="" correct="" extension="" type="" results="" in="" the="" copied="" file="" not="" integrating="" with="" the="" zq—pc="" zq—pc-sr001.="">
5. Firmware Upgrade Z9-PC / Z9-PC-SR001
User & Reference Manual
LUM0077AA Rev Sep-2018 Page 37 of 423 Copyright © 2018FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
The ZumLink window is similar to Figure 18:
Figure 18: 1_Device_Firmware_v1_1_0_1.pkg.txt File Dropped in the
ZumLink window
The .pkg or .pkg.txt file will disappear after approximately 6-10 minutes.
8. WAIT a few minutes for the FreeWave Drivers and ZumLink windows to close.
The Z9-PC / Z9-PC-SR001 automatically reboots.
Warning! DO NOT remove power from the Z9-PC / Z9-PC-SR001 during the firmware
upgrade process!
If power is removed prematurely during the upgrade process, the Web Interface pages
may not be accessible.
Reinstall the .pkg file and WAIT for the file upgrade process to complete.
The LEDs (on page 416) indicated the upgrade process.
The FreeWave Drivers and ZumLink windows re-open when the .pkg or .pkg.txt
upgrade file is applied.
9. In the ZumLink window, double-click the connected Z9-PC / Z9-PC-SR001.
The files of the Z9-PC / Z9-PC-SR001 appear in the window.
10. Locate and select the downloaded 2_Radio_Firmware_v1_0_7_1.fcf upgrade file.
(Figure 19)
Caution: A .pkg or .fcf file extension is required for Windows® 7.
A.pkg.txt or .fcf.txt file extension may be required for some versions of Windows® 8,
Windows® 8.1, and Windows® 10.
Failure to save the file with the correct extension type results in the copied file NOT
inte